Files
MultiPhysicsVault/wiki/concepts/Abaqus Prescribed Conditions and Amplitudes.md
김경종 553842ac3b
Tests / Hermetic test suite (push) Has been cancelled
Tests / Skill frontmatter validation (push) Has been cancelled
modify wiki
2026-06-02 16:57:41 +09:00

3.1 KiB

type, title, complexity, domain, created, updated, address, aliases, tags, status, related, sources, source_refs
type title complexity domain created updated address aliases tags status related sources source_refs
concept Abaqus Prescribed Conditions and Amplitudes intermediate computational-mechanics 2026-06-01 2026-06-01 c-000117
Abaqus prescribed conditions
Abaqus amplitude curves
Abaqus time-dependent loads
concept
finite-element-method
abaqus
prescribed-conditions
amplitudes
current
Abaqus-Analysis-User-s-Guide-Volume-V
Abaqus Initial and Boundary Conditions
Abaqus Loads and Predefined Fields
Abaqus Input File Syntax
Abaqus General and Linear Perturbation Steps
Abaqus Nonlinear Solution Control
Abaqus-Analysis-User-s-Guide-Volume-V
source raw_path raw_files md_indices match confidence
Abaqus-Analysis-User-s-Guide-Volume-V .raw/AbaqusAnalysisUserGuide5/
AbaqusAnalysisUserGuide5_004.md
AbaqusAnalysisUserGuide5_017.md
AbaqusAnalysisUserGuide5_013.md
AbaqusAnalysisUserGuide5_012.md
4
17
13
12
heuristic-heading-keyword high

Abaqus Prescribed Conditions and Amplitudes

Definition

Abaqus prescribed conditions are externally imposed model quantities such as initial conditions, boundary conditions, loads, assembly loads, connector motions, and predefined fields. Amplitudes define their time or frequency variation.

How It Works

A prescribed condition can be applied as model data or history data depending on the feature. Boundary conditions, loads, and predefined fields can refer to named amplitude curves. Without an explicit amplitude, Abaqus applies default ramp or step behavior depending on the product, procedure, and condition type.

Amplitude definitions can be tabular, equally spaced, periodic, modulated, smooth step, exponential, solution-dependent, user-defined, or imported from alternate files. They can use step time or total time and can be shared by many conditions.

In Abaqus/Standard, removing a displacement or rotation boundary condition in a stress/displacement analysis converts it to an applied conjugate flux that is then ramped or stepped to zero. This makes condition removal part of the load history rather than a purely symbolic edit.

Why It Matters

The same nominal load or boundary value can produce very different nonlinear and dynamic results depending on its amplitude history. Prescribed conditions are therefore part of the analysis strategy, not just input decoration.