Abaqus Input Subset

Purpose

This document defines the Abaqus .inp subset supported by FESA Phase 1.

FESA aims for strict, explicit compatibility with a small subset rather than partial silent interpretation of the full Abaqus language.

Source Basis

Phase 1 Supported Keywords

Keyword Status FESA Object Notes
*Node Supported Node 3D coordinates only
*Element Supported Element TYPE=S4 maps to MITC4
*Nset Supported NodeSet Explicit list and GENERATE should be supported
*Elset Supported ElementSet Explicit list and GENERATE should be supported
*Material Supported Material NAME required
*Elastic Supported LinearElasticMaterial Isotropic E, nu only
*Shell Section Supported ShellProperty Homogeneous shell section only
*Boundary Supported FixBoundaryCondition Direct zero-valued constraints
*Cload Supported NodalLoad Concentrated forces/moments
*Step Supported StepDefinition Static linear Phase 1 step
*Static Accepted inside *Step LinearStaticAnalysis Optional for Phase 1
*End Step Supported Step delimiter Required for explicit step closure

Unsupported keywords must produce a clear diagnostic unless explicitly listed as ignorable metadata.

General Parser Rules

FESA parser rules:

  • Keyword names and parameter names are case-insensitive.
  • Keyword lines start with *.
  • Comment lines start with ** and are ignored.
  • Data fields are comma-separated.
  • Empty trailing fields may be ignored.
  • Numeric data may use decimal or scientific notation.
  • D exponents should be accepted and normalized as E exponents.
  • Keyword continuation with a trailing comma should be supported for keyword lines.
  • Data continuation should be supported only where this document explicitly allows it.
  • Abbreviated Abaqus keywords are not supported in Phase 1. Require exact keyword names after case normalization.
  • Include files through INPUT= are not supported in Phase 1.
  • Part/Assembly/Instance syntax is not supported in Phase 1 unless added by ADR.

Labels and Names

Rules:

  • Set and material labels are stored case-insensitively by default.
  • Preserve the original spelling for diagnostics and result metadata.
  • Labels must start with a letter unless quoted.
  • Quoted labels may be accepted, but Phase 1 should warn if quoting is required for disambiguation.
  • Labels beginning and ending with double underscores are reserved and should be rejected.

*Node

Supported form:

*Node
node_id, x, y, z

Rules:

  • node_id is signed 64-bit integer.
  • Coordinates are double.
  • 2D node definitions are not supported for MITC4.
  • Duplicate node ids are an error.
  • Node ids need not be contiguous.

*Element

Supported form:

*Element, type=S4, elset=EALL
element_id, n1, n2, n3, n4

Rules:

  • TYPE=S4 maps directly to FESA MITC4.
  • TYPE=S4R is not supported in Phase 1. It is reserved for future support.
  • Element and node ids are signed 64-bit integers.
  • Four node connectivity entries are required.
  • Duplicate element ids are an error.
  • Missing nodes are an error.
  • If ELSET is given, the element is added to that element set.
  • Element node ordering follows Abaqus shell ordering and determines the positive normal by right-hand rule.

*Nset and *Elset

Supported explicit form:

*Nset, nset=FIXED
1, 2, 3, 4

Supported generated form:

*Elset, elset=EALL, generate
1, 100, 1

Rules:

  • Explicit lists may span repeated data lines.
  • GENERATE means start, end, increment.
  • The increment must be positive.
  • Set references to other sets are not required in Phase 1.
  • UNSORTED is not required in Phase 1.
  • Duplicates should be deduplicated while preserving a deterministic order for diagnostics.
  • Missing referenced ids should be reported when the set is consumed by a property, load, or boundary condition.

*Material and *Elastic

Supported form:

*Material, name=STEEL
*Elastic
E, nu

Rules:

  • Only isotropic linear elasticity is supported in Phase 1.
  • Temperature dependence, field-variable dependence, orthotropic elasticity, plasticity, density, and damping are unsupported.
  • E must be positive.
  • nu must be in a physically meaningful isotropic range. For Phase 1, reject nu <= -1.0 or nu >= 0.5.

*Shell Section

Supported form:

*Shell Section, elset=EALL, material=STEEL
thickness

Rules:

  • ELSET and MATERIAL are required.
  • Homogeneous single-layer shell sections only.
  • Thickness is double and must be positive.
  • Offsets, composite layups, section integration controls, orientations, temperature-dependent sections, and transverse shear stiffness overrides are unsupported in Phase 1.
  • Thermal-stress coupling is a future feature and must not be inferred from Phase 1 section data.

*Boundary

Supported direct form:

*Boundary
node_or_nset, first_dof, last_dof, magnitude

Rules:

  • node_or_nset may be a node id or node set label.
  • DOFs are 1..6.
  • If last_dof is omitted, constrain only first_dof.
  • Phase 1 supports zero-valued constraints. Omitted magnitude means zero.
  • Nonzero prescribed displacement/rotation is not a Phase 1 requirement.
  • Type-format boundary labels such as PINNED, XSYMM, or ENCASTRE are not supported unless later documented.
  • Constrained DOFs are eliminated by DofManager.

*Cload

Supported form:

*Cload
node_or_nset, dof, magnitude

Rules:

  • node_or_nset may be a node id or node set label.
  • DOFs are 1..6.
  • Translational DOFs define concentrated forces.
  • Rotational DOFs define concentrated moments.
  • FOLLOWER, AMPLITUDE, OP=NEW, file-based loads, buoyancy/drag/inertia loads, and cyclic symmetry loads are unsupported in Phase 1.

*Step, *Static, and *End Step

Supported form:

*Step, name=Step-1
*Static
*Cload
...
*Boundary
...
*End Step

Rules:

  • Phase 1 supports linear static steps.
  • NLGEOM is ignored only if explicitly false or absent. NLGEOM=YES must be rejected until nonlinear analysis is implemented.
  • Multiple steps may be parsed into Domain, but Phase 1 execution may initially support one active static step if documented in implementation steps.
  • Step activation should feed AnalysisModel.

Diagnostics

Required parser diagnostics:

  • Unknown keyword.
  • Unsupported keyword parameter.
  • Missing required parameter.
  • Duplicate node, element, material, property, or set definition.
  • Missing node in element connectivity.
  • Missing set used by shell section, boundary, or load.
  • Unsupported element type such as S4R.
  • Unsupported material or shell section mode.
  • Invalid DOF number.
  • Invalid generated set range.

Diagnostic messages should include file path, line number, keyword, and offending token.

Explicit Non-Goals

  • Abaqus Part, Assembly, Instance, and instance-qualified labels.
  • *Include.
  • S4R, S4R5, S8R, triangular shells, solid elements, beam elements.
  • Pressure loads.
  • RBE2/RBE3.
  • Nonzero prescribed displacements.
  • Amplitudes.
  • Local coordinate transforms.
  • Composite shell sections.
  • Thermal-stress input.