Integration in diffusive heat transfer elements

In all of the first-order elements (2-node links, 3-node triangles, 4-node quadrilaterals, 4-node tetrahedra, 6-node triangular prisms, and 8-node bricks) the internal energy storage term (associated with specific heat and latent heat storage) is integrated at the nodes. This integration scheme gives a diagonal internal energy matrix and improves the accuracy for problems with latent heat effects. Conduction contributions in these elements and all contributions in second-order elements use conventional Gauss schemes. Second-order elements are preferable for smooth problems without latent heat effects.

The one-dimensional element cannot be used in a mass diffusion analysis.

Forced convection heat transfer elements

These elements are available with linear interpolation only. They use an “upwinding” (Petrov-Galerkin) method to provide accurate solutions for convection-dominated problems (see “Convection/diffusion,” Section 2.11.3 of the Abaqus Theory Guide). Consequently, the internal energy (associated with specific heat storage) is not integrated at the nodes, which yields a consistent internal energy matrix and may cause oscillatory temperatures if strong temperature gradients occur along boundaries that are parallel to the flow direction.

Electromagnetic elements

These elements are available with linear edge-based interpolation only. The user-defined nodes define the geometry of the element but do not directly participate in the interpolation of the electromagnetic or, in the case of a magnetostatic analysis, the magnetic fields. However, temperature and predefined field variables are defined at the user-defined nodes and are interpolated to the integration points for evaluating material properties that are temperature and predefined field variable dependent.

Using element types C3D6 and C3D6T in Abaqus/Explicit analyses

When element types C3D6 and C3D6T are used in Abaqus/Explicit analyses, they appear in the output database (.odb) file as C3D6R and C3D6RT, respectively. In the data (.dat) file, C3D6 is referred to as C3D6R. You cannot specify C3D6R or C3D6RT as an element type for input.

28.1.2 ONE-DIMENSIONAL SOLID (LINK) ELEMENT LIBRARY

Products: Abaqus/Standard Abaqus/CAE

References

• “Solid (continuum) elements,” Section 28.1.1
• *SOLID SECTION

Overview

This section provides a reference to the one-dimensional solid (link) elements available in Abaqus/Standard. For structural link (truss) elements, refer to “Truss elements,” Section 29.2.1.

Element types

Diffusive heat transfer elements

DC1D22-node link
DC1D33-node link

Active degree of freedom

11

Additional solution variables

None.

Forced convection heat transfer elements

DCC1D22-node link
DCC1D2D2-node link with dispersion control

Active degree of freedom

11

Additional solution variables

None.

Coupled thermal-electrical elements

DC1D2E2-node link
DC1D3E3-node link

Active degrees of freedom

9, 11

Additional solution variables

None.

Acoustic elements

AC1D22-node link
AC1D33-node link

Active degree of freedom

8

Additional solution variables

None.

Nodal coordinates required

X, Y, Z

Element property definition

You must provide the cross-sectional area of the element; by default, unit area is assumed.

Input File Usage: *SOLID SECTION

Abaqus/CAE Usage: Property module: Create Section: select Beam as the section Category and Truss as the section Type

Element-based loading

Distributed heat fluxes

Distributed heat fluxes are available for elements with temperature degrees of freedom. They are specified as described in “Thermal loads,” Section 34.4.4.

Load ID(*DFLUX)Abaqus/CAELoad/InteractionUnitsDescription
BFBody heat flux $JL^{-3} \ T^{-1}$ Heat body flux per unit volume.
BFNUBody heat flux $JL^{-3} \ T^{-1}$ Nonuniform heat body flux per unit volume with magnitude supplied via user subroutine DFLUX.
S1Surface heat flux $JL^{-2} \ T^{-1}$ Heat surface flux per unit area into the first end of the link (node 1).
Load ID(*DFLUX)Abaqus/CAELoad/InteractionUnitsDescription
S2Surface heat flux $JL^{-2}$ $T^{-1}$ Heat surface flux per unit area into the second end of the link (node 2 or node 3).
S1NUNot supported $JL^{-2}$ $T^{-1}$ Nonuniform heat surface flux per unit area into the first end of the link (node 1) with magnitude supplied via user subroutine DFLUX.
S2NUNot supported $JL^{-2}$ $T^{-1}$ Nonuniform heat surface flux per unit area into the second end of the link (node 2 or node 3) with magnitude supplied via user subroutine DFLUX.

Film conditions

Film conditions are available for elements with temperature degrees of freedom. They are specified as described in “Thermal loads,” Section 34.4.4.

Load ID (*FILM)Abaqus/CAE Load/InteractionUnitsDescription
F1Not supported $JL^{-2}T^{-1}\theta^{-1}$ Film coefficient and sink temperature (units of $\theta$ ) at the first end of the link (node 1).
F2Not supported $JL^{-2}T^{-1}\theta^{-1}$ Film coefficient and sink temperature (units of $\theta$ ) at the second end of the link (node 2 or node 3).
F1NUNot supported $JL^{-2}T^{-1}\theta^{-1}$ Nonuniform film coefficient and sink temperature (units of $\theta$ ) at the first end of the link (node 1) with magnitude supplied via user subroutine FILM.
F2NUNot supported $JL^{-2}T^{-1}\theta^{-1}$ Nonuniform film coefficient and sink temperature (units of $\theta$ ) at the second end of the link (node 2 or node 3) with magnitude supplied via user subroutine FILM.

Radiation types

Radiation conditions are available for elements with temperature degrees of freedom. They are specified as described in “Thermal loads,” Section 34.4.4.

Load ID(*RADIATE)Abaqus/CAELoad/InteractionUnitsDescription
R1Surface radiationDimensionlessEmissivity and sink temperature (units of θ) at the first end of the link (node 1).
R2Surface radiationDimensionlessEmissivity and sink temperature (units of θ) at the second end of the link (node 2 or node 3).

Distributed impedances

Distributed impedances are available for elements with acoustic pressure degrees of freedom. They are specified as described in “Acoustic and shock loads,” Section 34.4.6.

Load ID(*IMPEDANCE)Abaqus/CAE Load/InteractionUnitsDescription
I1Not supportedNoneName of the impedance property that defines the impedance at the first end of the link (node 1).
I2Not supportedNoneName of the impedance property that defines the impedance at the second end of the link (node 2 or node 3).

Distributed electric current densities

Distributed electric current densities are available for coupled thermal-electrical elements. They are specified as described in “Coupled thermal-electrical analysis,” Section 6.7.3.

Load ID(*DECURRENT)Abaqus/CAELoad/InteractionUnitsDescription
CBFBody current $CL^{-3}T^{-1}$ Volumetric current source density.
CS1Surface current $CL^{-2}T^{-1}$ Current density at the first end of the link (node 1).
CS2Surface current $CL^{-2}T^{-1}$ Current density at the second end of the link (node 2 or node 3).

Element output

Heat flux components

Available for elements with temperature degrees of freedom.

HFL1 Heat flux along the element axis.

Electrical potential gradient

Available for coupled thermal-electrical elements.

EPG1 Electrical potential gradient along the element axis.

Electrical current density components

Available for coupled thermal-electrical elements.

ECD1 Electrical current density along the element axis.

Node ordering and face numbering on elements

text_image

1 end 1 2 end 2

2 - node element

flowchart
graph TD
    A["1"] --> B["2"]
    B --> C["3"]
    A -->|end 1| B
    C -->|end 2| B

3 - node element

Numbering of integration points for output

text_image

1 + 1 2

2 - node element

flowchart
graph TD
    1["1"] -->|×| 1
    1 -->|×| 2["2"]
    2 -->|×| 2
    2 -->|×| 3["3"]

3 - node element

28.1.3 TWO-DIMENSIONAL SOLID ELEMENT LIBRARY

Products: Abaqus/Standard Abaqus/Explicit Abaqus/CAE

References

• “Solid (continuum) elements,” Section 28.1.1
• *SOLID SECTION

Overview

This section provides a reference to the two-dimensional solid elements available in Abaqus/Standard and Abaqus/Explicit.

Element types

Plane strain elements

CPE33-node linear
CPE3H(S)3-node linear, hybrid with constant pressure
CPE4(S)4-node bilinear
CPE4H(S)4-node bilinear, hybrid with constant pressure
CPE4I(S)4-node bilinear, incompatible modes
CPE4IH(S)4-node bilinear, incompatible modes, hybrid with linear pressure
CPE4R4-node bilinear, reduced integration with hourglass control
CPE4RH(S)4-node bilinear, reduced integration with hourglass control, hybrid with constant pressure
CPE6(S)6-node quadratic
CPE6H(S)6-node quadratic, hybrid with linear pressure
CPE6M6-node modified, with hourglass control
CPE6MH(S)6-node modified, with hourglass control, hybrid with linear pressure
CPE8(S)8-node biquadratic
CPE8H(S)8-node biquadratic, hybrid with linear pressure
CPE8R(S)8-node biquadratic, reduced integration
CPE8RH(S)8-node biquadratic, reduced integration, hybrid with linear pressure

Active degrees of freedom

1, 2

Additional solution variables

The constant pressure hybrid elements have one additional variable relating to pressure, and the linear pressure hybrid elements have three additional variables relating to pressure.

Element types CPE4I and CPE4IH have five additional variables relating to the incompatible modes.

Element types CPE6M and CPE6MH have two additional displacement variables.

Plane stress elements

CPS33-node linear
CPS4(S)4-node bilinear
CPS4I(S)4-node bilinear, incompatible modes
CPS4R4-node bilinear, reduced integration with hourglass control
CPS6(S)6-node quadratic
CPS6M6-node modified, with hourglass control
CPS8(S)8-node biquadratic
CPS8R(S)8-node biquadratic, reduced integration

Active degrees of freedom

1, 2

Additional solution variables

Element type CPS4I has four additional variables relating to the incompatible modes.

Element type CPS6M has two additional displacement variables.

Generalized plane strain elements

CPEG3(S)3-node linear triangle
CPEG3H(S)3-node linear triangle, hybrid with constant pressure
CPEG4(S)4-node bilinear quadrilateral
CPEG4H(S)4-node bilinear quadrilateral, hybrid with constant pressure
CPEG4I(S)4-node bilinear quadrilateral, incompatible modes
CPEG4IH(S)4-node bilinear quadrilateral, incompatible modes, hybrid with linear pressure
CPEG4R(S)4-node bilinear quadrilateral, reduced integration with hourglass control
CPEG4RH(S)4-node bilinear quadrilateral, reduced integration with hourglass control, hybrid with constant pressure